| Date: 12/5/2007 | Time: 09:00 AM | Report ID: samplenew |
| Property: 9090 Builders Choice Way Brentwood, TN 37211 |
Customer: Mr. New Construction Mrs. New Construction |
Real Estate Professional: Susie Realtor Best Realty Company |
This home is new construction. Please review this report closely to determine if any item or component was not inspected due to incomplete work or no utilities. It is common that a new home can need painting or caulking again within the first 5 years due to normal shrinkage and new material. Settlement cracks found in homes usually occur within the first three years. Most builders give a one year warranty on materials and labor. For this reason, please consider another inspection within one year to get the most out of your warranty with your builder.
Client Is Present: No | Age Of Home: New Construction | Radon Test: No |
Temperature: Below 65 | Rain in last 3 days: Yes | Style of Home: Contemporary |
Weather: Cloudy, Light Rain |
| Styles & Materials DRIVEWAY:
AGGREGRATE |
|||||||||||||||||||||||||||||||||||
| Styles & Materials VIEWED ROOF FROM: GROUND WITH BINOCULARS INTERIOR WINDOWS ROOF-TYPE: GABLE ROOF COVERING: ARCHITECTURAL CHIMNEY:
CEMENT FIBER |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
2.5 ![]() |
2.7 ![]() |
![]() |
| Styles & Materials SIDING MATERIAL:
BRICK VENEER VINYL TRIM METAL TRIM |
||||||||||||||||||||||||||||||||||||||||||
![]() |
| Styles & Materials APPURTENANCE:
DECK WITH STEPS PATIO |
||||||||||||||||||||||||||||
4.1 ![]() |
![]() |
| Styles & Materials ENTRY DOORS: STEEL INSULATED GLASS WOOD WINDOWS:
VINYL |
||||||||||||||||||||||||||||||||||||||||||
5.0 ![]() |
![]() |
![]() |
Front door glass and front door sidelight glass up to 60" must be safety glass. Generally safety
glass is distinguished with etching in the corner. I was unable to locate safety glass etching
symbol at this location. Suggest confirming with the builder safety glass is present.
| Styles & Materials OPENER MANUFACTURER: 1/2 HORSEPOWER LIFT-MASTER GARAGE DOOR MATERIAL: METAL INSULATED TYPE:
TWO AUTOMATIC |
|||||||||||||||||||||||||||||||||||||||||||||||||
6.0 Single garage door did not function as intended. Must hold button down completely to operate
door. Generally this indicates electronic sensors are not aligned.
| Styles & Materials CEILING MATERIALS: DRYWALL FLOOR COVERING(S): CARPET TILE FINISHED WOOD WALL MATERIAL: DRYWALL INTERIOR DOORS: RAISED PANEL WINDOW TYPES: SINGLE HUNG/TILT/INSULATED COUNTERTOP: CULTURED MARBLE GRANITE CABINETRY: LAMINATE WINDOW MANUFACTURER:
CURADCO |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
7.3 Master bath window must be tempered. I was unable to locate tempered etching on window.
Suggest confirming with builder this window is safety glass.
| Styles & Materials ELEC. PANEL MANUFACTURER: SQUARE D ELECTRICAL CONDUCTORS: BELOW GROUND ALUMINUM 120/240 VOLT PANEL CAPACITY: 225 AMP PANEL TYPE: CIRCUITS BRANCH WIRE 15 and 20 AMP: COPPER WIRING METHODS:
ROMEX |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
8.7 ![]() |
| Styles & Materials PACKAGE UNIT BRAND: BRYANT DATE OF MFG:: 2007 ELECTRIC HEAT PUMP: BRYANT BTU RANGE: 115000 NUMBER OF HEAT SYSTEMS (excluding wood): TWO FUEL SOURCE: GAS ELECTRIC HEAT TYPE: FORCED AIR HEAT PUMP (FORCED AIR) FILTER TYPE: DISPOSABLE FILTER SIZE: (Four filters) 14x14 14x30 DUCTWORK:
INSULATED |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
| Styles & Materials CENTRAL AIR MANUFACTURER: BRYANT DATE OF MFG:: 2007 NUMBER OF A/C UNITS:
TWO |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
| Styles & Materials ATTIC INFO: PULL DOWN STAIRS STORAGE LIGHT IN ATTIC ROOF STRUCTURE: STICK-BUILT SHEATHING 2 X 8 RAFTERS CEILING STRUCTURE:
6'" OR BETTER |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Styles & Materials ATTIC INSULATION: BLOWN FIBERGLASS R- VALUE: R-30 OR BETTER ATTIC VENTILATION: SOFFIT VENTS RIDGE VENTS EXHAUST FAN TYPES: FAN ONLY DRYER POWER SOURCE: 24O ELECTRIC DRYER VENT:
METAL |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12.3 ![]() |
![]() |
| Styles & Materials MANUFACTURER: STATE DATE OF MFG:: 2007 CAPACITY: 50 GAL PLUMBING SUPPLY: PEX DISTRIBUTION: PEX PLUMBING WASTE: PVC WATER SOURCE: PUBLIC WATER HEATER POWER SOURCE: ELECTRIC CLOTHES WASHER DRAIN SIZE:
2" DIAMETER |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
Master bath tub is not secured whatsoever. It can easily be moved by hand. Tub needs properly
securing and sealing with high quality silicone. Not adequate hot water at master shower. Checked
several times and at best water is luke warm.![]() |
13.2 ![]() |
![]() |
![]() |
13.6 ![]() |
| Styles & Materials OPERABLE FIREPLACES: ONE TYPES OF FIREPLACES:
VENTED GAS LOGS |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
| Styles & Materials METHOD USED TO OBSERVE CRAWLSPACE: CRAWLED FOUNDATION: MASONRY BLOCK POURED CONCRETE PADS BLOCK PIERS FLOOR STRUCTURE: 2 X 8 or10 WOOD JOISTS WALL STRUCTURE:
2 X 4 WOOD |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
15.3 ![]() |
![]() |
| Styles & Materials RANGE/OVEN: JENN AIR DISHWASHER: JENN AIR BUILT-IN MICROWAVE: JENN AIR DISPOSER: IN SINK ERATOR EXHAUST/RANGE HOOD: JENN AIR VENTED COOKTOP:
JENN AIR |
|||||||||||||||||||||||||||||||||||||||||||||||||
![]() |

The following items or discoveries indicate that these systems and/ or components do not function as intended or adversely affects the habitability of the dwelling; or appear to warrant further investigation by a licensed specialist prior to close of escrow, or requires subsequent observation. This summary shall not contain recommendations for routine upkeep of a system or component to keep it in proper functioning condition or recommendations to upgrade or enhance the function, efficiency, or safety of the home. This Summary is not the entire report. The complete report may include additional information of concern to the customer. It is recommended that the customer read the complete report.
General Summary| 2.5 | SKYLIGHTS, CHIMNEYS AND ROOF PENETRATIONS |
| Functional | |
|
I was only able to view chimney flashing with high power binoculars, however it does not appear
chimney flashing is properly secured to chimney or roof line. A large gap exist that can potentially
allow moisture intrusion. Recommend builders roofing contractor investigate further and make
appropriate repairs if needed. |
| 2.7 | ARE DOWNSPOUTS OR DRAINAGE PROVIDED PROPERLY |
| Yes | |
|
At a minimum splashblocks are needed at all locations.(Picture 1) Where practical a better option
than splashblocks are drain line extensions.(Picture 2) |
General Summary| 4.1 | DECKS, STAIRS AND HANDRAILS OR BALCONIES |
| Functional | |
|
Although regulations vary by county, the general requirement for handrails states "gripable hand
rail required if four or more risers exist". Handrail at deck does not appear gripable. Recommend
consulting the builder and local codes administrator for clarification. (Picture 2) |
General Summary| 5.0 | OUTSIDE APPEARANCE OF WINDOWS OR SKYLIGHTS |
| REPAIR OR REPLACE | |
|
Left upper sidelight at front porch broken, needs replace.(Picture 1) Upper portion of upper level
window right side of home has not been properly sealed with silicone at brick. Repairs
needed.(Picture 2) |
|
|
Front door glass and front door sidelight glass up to 60" must be safety glass. Generally safety
glass is distinguished with etching in the corner. I was unable to locate safety glass etching
symbol at this location. Suggest confirming with the builder safety glass is present. |
General Summary| 6.0 | GARAGE DOOR OPERATORS |
| REPAIR OR REPLACE | |
|
Single garage door did not function as intended. Must hold button down completely to operate
door. Generally this indicates electronic sensors are not aligned. |
General Summary| 7.3 | WINDOWS (Representative number) |
| Functional | |
|
Master bath window must be tempered. I was unable to locate tempered etching on window.
Suggest confirming with builder this window is safety glass. |
Electrical| 8.7 | CONNECTED DEVICES, FIXTURES OR LOOSE WIRING (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls) |
| Functional | |
|
Right master bath light fixture needs properly securing. |
General Summary| 12.3 | FOUNDATION VENTILATION |
| REPAIR OR REPLACE | |
|
Virtually all foundation vents or mortared in a stationary position disabling their ability to open and
shut. Recommend all vents be made to work properly.(Picture 1) In my opinion foundation vent
located at patio is below patio level and may allow water into the crawl space. Recommend this be
monitored, if moisture intrusion occurs corrective measures should be considered.(Picture 2) |
Plumbing| 13.0 | INTERIOR WATER SUPPLY AND DISTRIBUTION SYSTEMS AND FIXTURES |
| Functional | |
|
Master bath tub is not secured whatsoever. It can easily be moved by hand. Tub needs properly
securing and sealing with high quality silicone. Not adequate hot water at master shower. Checked
several times and at best water is luke warm. |
| 13.2 | ANY LEAKS OR CROSS-CONNECTIONS ON SUPPLY OR WASTE LINES |
| No | |
|
Knob missing at hose spigot right side of home. Spigot needs properly sealing to brick.(Picture 1)
Main water supply line coming from street ideally should be in hangers and better
supported.(Picture 2) |
| 13.6 | IS THE T&P VALVE PIPED WITHIN 6 INCHES OF FLOOR |
| REPAIR OR REPLACE | |
|
Existing piping for T&P valve on water heater is missing. T&P (Test and Pressure) valve on water
heater needs a 3/4 threaded pipe to extend within 6 inches of floor for safety. (PVC is not approved
for hot water use). |
General Summary| 15.3 | ANY DEBRIS IN BASEMENT OR CRAWLSPACE |
| Yes | |
|
All wood and any other construction debris needs removing from above and underneath vapor
barrier in crawl space. If left unattended these items breed wood eating organisms. |